Abstract
A 65-year-old female presented with history of exertional chest pain. ECG was unremarkable, Troponin was mildly increased, Echocardiogram showed normal left ventricular systolic function. Coronary Angiography via right radial artery revealed a chronic total occlusion in the left anterior descending artery (LAD) (Figure 1). PCI was attempted but complicated with vessel perforation in the right mid forearm caused by the guiding catheter (Video 1). Balloon assisted tracking with 2.0x15mm compliant balloon inflated to 8ATM over a 0.014” coronary wire at the tip of a 5F guiding catheter was performed; allowing the safe delivery of the guiding catheter to the aortic root (Video 2). PCI was performed with overlapping stents from proximal to distal LAD. Final result (Video 3) showed successful PCI, with no complications. Angiography of the radial artery showed no dye extravasation and only mild spasm consistent with sealing of the perforation. This technique was first described by Dr. Tejas Patel1. References: 1.Patel T, Shah S, Pancholy S, Rao S, Bertrand OF, Kwan T. Balloon-assisted tracking: a must- know technique to overcome difficult anatomy during transradial approach. Catheter Cardiovasc Interv. 2014;83(2):211-20.
Article Full Text
January 1st, 2019 Rufai Y, Image: Balloon Assisted Tracking to treat radial … DOI: http://dx.doi.org/10.25239/SHJ/Vol6/No2/Image
Cardiology Image Balloon Assisted Tracking to Treat Radial Artery Perforation Author: Dr. Yassin Rufai*, Dr. Afra A. M. Elhassan*, Dr. Salaheldin Abusin^
*Fedail Hospital, Khartoum, Sudan ^Corresponding Author, salah.abusin@gmail.com
safe delivery of the guiding catheter to A 65-year-old female presented with the aortic root (Video 2). PCI was history of exertional chest pain. ECG was performed with overlapping stents from unremarkable, Troponin was mildly proximal to distal LAD. Final result (Video increased, Echocardiogram showed 3) showed successful PCI, with no normal left ventricular systolic function.
complications. Angiography of the radial Coronary Angiography via right radial artery showed no dye extravasation and artery revealed a chronic total occlusion only mild spasm consistent with sealing in the left anterior descending artery of the perforation. This technique was (LAD) (Figure 1). PCI was attempted but first described by Dr. Tejas Patel1. complicated with vessel perforation in the
References
- right mid forearm caused by the guiding catheter (Video 1). Balloon assisted 1.Patel T, Shah S, Pancholy S, Rao S, Bertrand tracking with 2.0x15mm compliant OF, Kwan T. Balloon-assisted tracking: a mustknow technique to overcome difficult anatomy balloon inflated to 8ATM over a 0.014” during transradial approach. Catheter coronary wire at the tip of a 5F guiding Cardiovasc Interv. 2014;83(2):211-20.
- catheter was performed; allowing the January 1st, 2019 Rufai Y, Image: Balloon Assisted Tracking to treat radial … DOI: http://dx.doi.org/10.25239/SHJ/Vol6/No2/Image
- Figure 1 Chronic Total Occlusion in Proximal LAD
- Video 1. Dye Extravasation (Click to view video or visit https://streamable.com/n0vks)
- Video 2. Balloon Assisted Tracking (Click to view video or visit https://streamable.com/5u4lo) Video 3. Final Result (Click to view video or visit https://streamable.com/rnb1c)